Identify the LVL Manufacturer
First, identify the product you intend to use. Different manufacturers may offer LVL beams with different design properties. A span value for one brand should not automatically be applied to another.
Engineered Wood Beam Calculator
Estimate the load, bending moment, support reactions, and theoretical deflection of an LVL beam. Enter your beam dimensions, floor or roof loads, and tributary width to understand the structural demands on your beam.
Free Online Calculator
Your Results
Your beam receives an estimated distributed load of 550 pounds per linear foot under the entered assumptions.
Deflection is estimated using a simply supported beam with a uniformly distributed load and the entered modulus of elasticity.
These calculations are preliminary engineering estimates, not an LVL size approval. They do not check bending capacity, shear capacity, bearing, lateral stability, connections, multi-ply fastening, load combinations, or code compliance. A qualified professional must verify the actual beam design.
The deflection formula assumes a simply supported beam with a uniformly distributed load. It is not a complete LVL design method.
LVL stands for laminated veneer lumber. It is an engineered wood product made by bonding thin wood veneers together under heat and pressure using structural adhesives.
The veneers are generally arranged with their grain running in the same direction, creating a strong and relatively consistent structural member.
LVL is commonly manufactured as beams, headers, and other structural components.
Compared with conventional solid-sawn lumber, LVL offers several advantages:
However, not all LVL products have the same design values. Always use the technical information for the specific manufacturer's product.
An LVL span calculator uses beam dimensions, loading information, and support conditions to help determine whether a particular LVL member can safely span a given distance.
The calculator needs more information than simply the distance between two walls.
Information used when evaluating an engineered beam
| Input | What it means |
|---|---|
| Beam span | Distance between the beam's supports |
| Beam depth | Vertical dimension of the LVL |
| Beam thickness | Thickness of one LVL ply or the complete beam |
| Number of plies | Number of LVL members fastened together |
| Load | Weight or force supported by the beam |
| Load type | Floor, roof, snow, or other structural loading |
| Support condition | Whether the beam is simply supported or continuous |
| Deflection limit | Maximum permitted beam movement |
| LVL product | Manufacturer and product grade |
Some engineering calculators also require bearing length, lateral restraint, load duration, and connection information.
The results should be checked against the manufacturer's design guide and applicable building requirements. Boise Cascade's BC Calc, for example, allows users to enter member geometry, loads, holes, and other relevant information before selecting an engineered wood product.
There is no single maximum span for every LVL beam.
A 9½-inch LVL beam will not have the same capacity as a 14-inch beam of the same product and thickness. Similarly, a two-ply beam and a three-ply beam may have different capacities.
The allowable span depends on several factors:
For example, a beam supporting a residential floor may have different design requirements from an LVL beam supporting a roof with substantial snow loads.
A longer span generally increases bending and deflection demands. A suitable beam must satisfy all relevant structural checks, not just one span measurement.
An LVL beam span table shows the allowable span or load capacity for specific beam sizes and design conditions.
Unlike a general dimensional-lumber span chart, an LVL table is usually tied to a particular manufacturer's product and grade.
For example, manufacturers such as Boise Cascade publish product-specific design guides for their Versa-Lam LVL beams and headers. These guides include design properties, span information, and installation requirements.
A typical LVL design table may include:
| Table information | Purpose |
|---|---|
| Beam depth | Identifies the vertical beam dimension |
| Beam thickness | Identifies the thickness of the member |
| Number of plies | Indicates the beam configuration |
| Span | Shows the distance between supports |
| Total load | Represents the combined supported load |
| Live load | Represents variable or occupancy-related loads |
| Deflection limit | Limits how much the beam can bend |
| Design properties | Shows the structural properties used in calculations |
Some tables show allowable loads for different spans, while others provide maximum span values for specific load assumptions.
Always read the notes below the table. A span value may depend on a particular load distribution, support condition, deflection limit, and installation arrangement.
Follow these steps when using a manufacturer's LVL span table.
First, identify the product you intend to use. Different manufacturers may offer LVL beams with different design properties. A span value for one brand should not automatically be applied to another.
Look for the product's grade or design designation. You may see labels such as 1.7E, 1.8E, or 2.0E. The E value refers to the modulus of elasticity, which describes material stiffness.
Find the correct beam depth and thickness in the table. Common examples include 7¼, 9¼, 9½, 11¼, 11⅞, and 14 inches.
An LVL beam may consist of one or more members connected together. Common arrangements include single-ply, double-ply, triple-ply, and four-ply beams.
Identify the loads supported by the beam. Floor beams may support the floor structure, occupants, and furniture. Roof beams may support roof framing, roofing materials, snow loads, and other applicable loads.
Find the applicable span or load value in the table. Confirm that the selected beam satisfies the required strength and deflection limits. Also check bearing and connection requirements.
A multi-ply beam is not automatically designed by multiplying a single-ply capacity by the number of members. The manufacturer must specify the applicable multi-ply design values, fastening arrangement, and load-sharing assumptions.
LVL beams are available in different depths and thicknesses to suit different framing requirements.
| LVL beam configuration | Common application |
|---|---|
| Single-ply LVL | Headers and smaller structural members |
| Double-ply LVL | Floor beams and structural openings |
| Triple-ply LVL | Heavier floor or roof beam applications |
| Four-ply LVL | Larger engineered beam applications |
These are general examples, not sizing recommendations. The correct configuration depends on the actual load and structural design.
Beam depth is an important factor in structural performance.
Increasing the depth of a beam can significantly improve its bending stiffness. This can help control deflection and support longer spans under comparable conditions.
However, a deeper beam still needs adequate bending strength, shear capacity, bearing, and lateral stability.
LVL thickness determines the width of the member.
If a wider beam is needed, multiple LVL plies may be used. The plies must be connected according to the manufacturer's instructions so that the beam performs as designed.
Before selecting an LVL beam, you need to understand how much load it will support.
Structural loads are commonly expressed as:
For a uniformly distributed floor load, the beam's approximate line load can be calculated using:
Where w = load per linear foot (plf), q = floor load (psf), and b = tributary width (ft).
The tributary width is the floor width whose load is transferred to the beam.
Assume:
First, calculate the total floor load:
Then calculate the approximate line load:
The beam receives approximately 550 pounds per linear foot from this floor area, before considering the beam's self-weight and other applicable loads.
This is a simplified load conversion, not a complete beam design. Actual tributary areas, load combinations, concentrated loads, and support reactions must be evaluated.
Consider a hypothetical floor beam with the following information:
| Design information | Example |
|---|---|
| Beam span | 16 feet |
| Tributary width | 10 feet |
| Live load | 40 psf |
| Dead load | 15 psf |
| Total floor load | 55 psf |
| Approximate line load | 550 plf |
The first step is to calculate the load transferred to the beam.
For a simply supported beam carrying a uniformly distributed load, the theoretical maximum bending moment is:
Where M = maximum bending moment, w = uniformly distributed load, and L = beam span.
Substituting the example values:
This is a simplified beam-analysis result. It does not establish that a particular LVL size is adequate.
The selected LVL must still be checked for bending, shear, deflection, bearing, stability, connections, and the actual applicable load combinations.
Several factors influence how far an LVL beam can span.
Deeper beams generally have greater bending stiffness. This can reduce deflection and increase the potential span when other design conditions remain comparable.
The manufacturer's design properties determine how the LVL performs under structural loads.
The modulus of elasticity (E) is an important measure of stiffness, while bending and shear design values help determine the beam's strength.
Multiple LVL members can be assembled into a wider beam. However, the load must be transferred properly between plies. Follow the manufacturer's fastening and connection requirements.
A beam supporting a heavy floor or roof generally requires more capacity than one supporting a lighter structure. Both permanent and variable loads need to be considered.
A simply supported beam behaves differently from a continuous beam supported at multiple locations. The support arrangement affects bending moments, shear forces, and deflection.
A beam may satisfy bending-strength requirements but still deflect more than permitted.
Common design checks include live-load and total-load deflection limits. The appropriate criteria depend on the application and governing design requirements.
The ends of the LVL beam need adequate bearing support. The support must safely transfer the beam reaction into the supporting wall, column, or foundation.
LVL and solid-sawn lumber are both used in structural framing, but they have different manufacturing processes and structural characteristics.
| Feature | LVL beam | Solid-sawn lumber |
|---|---|---|
| Manufacturing | Bonded wood veneers | Milled from solid timber |
| Structural properties | Engineered and product-specific | Vary with species and grade |
| Dimensional consistency | Generally more uniform | Can vary with natural wood characteristics |
| Available dimensions | Manufacturer-specific engineered sizes | Standard dimensional lumber sizes |
| Typical applications | Headers, beams, and structural framing | Joists, rafters, beams, and general framing |
LVL can be useful when a project needs a structural member with specific engineered properties. However, the choice between LVL and solid lumber should be based on the design, availability, installation requirements, and cost.
LVL can also be used in roof framing, including certain rafter and structural roof-beam applications.
However, LVL rafter span tables are not interchangeable with floor-beam span tables.
A roof rafter must be evaluated using roof-specific information, including:
Manufacturers may provide separate design guidance for LVL beams, headers, joists, and other applications. Use the guide that matches the actual product and intended use.
For conventional roof framing information, see the relevant roof rafter span guidance.
Avoid these mistakes when estimating an LVL beam size:
An LVL span calculator is a tool used to estimate the required size or allowable span of a laminated veneer lumber beam. It uses information such as beam dimensions, supported loads, span, product properties, and support conditions.
The maximum span depends on the LVL product, beam depth, thickness, number of plies, loading, support conditions, and deflection requirements. Check the manufacturer's span tables or use an appropriate engineering calculator.
A 16-foot span alone is not enough to determine the correct LVL beam size. You also need the supported load, tributary width, product grade, number of plies, support conditions, and deflection requirements.
The E designation refers to the modulus of elasticity, a measure of stiffness. For example, 2.0E represents a nominal modulus of elasticity of 2.0 million psi for the specified product. It does not independently establish the beam's allowable span or complete load capacity.
A double LVL beam consists of two LVL members connected together. It can provide greater capacity than a comparable single-ply member when designed and connected correctly. The actual capacity depends on the product specifications, fastening, load distribution, and structural design.
Yes. Certain LVL products can be used in roof framing when their design properties and installation requirements are appropriate for the application. Use roof-specific design information rather than floor-beam span tables.
LVL is manufactured by bonding thin wood veneers together, generally with their grain running in the same direction. Glulam is manufactured by bonding multiple layers of dimensioned lumber together. Both are engineered wood products, but their design properties and applications differ.
A typical simply supported LVL beam requires support at both ends. Other structural arrangements may include continuous beams or cantilevered sections, but they require appropriate engineering design.
Do not drill or cut holes in an LVL beam without checking the manufacturer's instructions and applicable structural requirements. Unapproved holes and notches can reduce beam capacity.
No. LVL manufacturers use different product specifications and design properties. Always use the current span table or design guide for the exact product being installed.
LVL Beam Planning
An LVL span calculator can help estimate the size and capacity demands of an engineered wood beam, but the correct selection depends on more than the distance between supports.
Beam depth, thickness, product grade, number of plies, supported load, bearing, and deflection requirements all influence the final design.
Use manufacturer-specific span tables and verify the structural requirements before choosing an LVL beam. For complex loading conditions, unusual support arrangements, or long spans, have the design checked by a qualified structural professional.
Calculate Your Beam Loads